Product Introduction
The atomic absorption spectrophotometer is fully PC-controlled. Optional graphite furnace, autosampler and hydride generator are available flexibly. A unique optical-mechanical design, a safe and convenient flame system, optional background correction technology, and convenient features provided by the workstation are ideal for your quest for automated and accurate test results.
Product Features
1. Excellent total reflection optical system ensures excellent signal-to-noise ratio of the instrument.
2. Comprehensive and safe intelligent gas control module.
3. Excellent full-band deuterium lamp background correction technology and high-performance self-absorption dual background correction.
4. Fully automatic instrument control, the light source supports high-performance element lights, and it can be completed quickly with one click.
5. 360-degree rotation design of the eight-lamp base in the original lamp position.
6. New atomizer and smart elevator.
7. Simple, professional, automatic, fully operational RG WIN AAS workstation software under Microsoft window system.
Technical Data
|
Model |
AA 7804 |
AA 7808 |
AA 7818 |
AA 7828 |
|
|
|
Optical system |
Single beam |
Double beam |
|
|||
|
Monochromator |
Czerny-Turner type with a focal length of 350 mm |
|
||||
|
Grating |
Holographic diffraction with 1800 lines/mm |
|
||||
|
Wavelength range |
190-900 nm |
|
||||
|
Slits |
Automatic slit selection of 0.1, 0.2, 0.4, 0.7, 1.4, 2.0 nm |
|
||||
|
Wavelength repeatability |
± 0.1 nm |
±0.1nm |
± 0.05 nm |
±0.05 nm |
|
|
|
Wavelength accuracy |
± 0.3 nm |
± 0.2 nm |
± 0.15 nm |
±0.15 nm |
|
|
|
lamp |
Automatic 4 lights turret |
Automatic 8-light turret |
|
|||
|
Reading mode |
T, A, C |
|
||||
|
Luminosity range |
0-125%,-0.1-3.00A |
|
||||
|
Static baseline drift (Cu) |
≤ 0.004A/30 minutes |
≤ 0.003A/30 minutes |
≤ 0.002A/30 minutes |
≤0.002A/30 min |
|
|
|
Dynamic baseline drift (Cu) |
≤ 0.006A/15 minutes |
≤ 0.005A/15 minutes |
≤ 0.004A/15 minutes |
≤0.004A/15 min |
|
|
|
Background correction |
Deuterium (D2) background correction |
Deuterium (D2) background correction versus self-absorbing background correction |
|
|||
|
Flame |
Characteristics: concentration |
≤ 0.04ug/ml |
≤ 0.035 μg/ml |
≤0.035ug/ml |
≤0.035ug/ml |
|
|
Limit of detection (Cu) |
≤ 0.008ug/ml |
≤ 0.006ug/ml |
≤ 0.004ug/ml |
≤0.004ug/ml |
|
|
|
Repeatability (Cu) |
Rsd ≤ 1% |
Rsd ≤ 0.6% |
Rsd ≤ 0.5% |
RSD≤0.5% |
|
|
|
Acetylene flow control |
Automatic 12 levels |
|
||||
|
Air-assisted control |
Automatic 4 levels |
|
||||
|
Ignition method |
Computer control |
|
||||
|
detector |
Wide range UV-sensitive photomultiplier tube |
|
||||
|
Burner head |
Titanium 100 mm burner for air/acetylene operation |
|
||||
|
Nebulizer |
High efficiency glass atomizer |
|
||||
|
Spray room |
Corrosion-resistant material spraying chamber |
|
||||
|
Safety |
Automatically shut off gas in case of low pressure, power outage, stalling or burner mismatch |
|
||||
|
Graphite Furnace |
Feature quantity |
Cd≤ 1pg, Cu≤ 22pg |
Cd≤ 0.8pg, Cu≤ 20pg |
Cd≤0.8pg, Cu≤20pg |
|
|
|
Detection Limit (Cu) |
Cd≤ 1.5pg, Cu≤ 20pg |
Cd≤ 1.0pg, Cu≤ 10pg |
Cd≤ 0.8pg, Cu≤ 5pg |
|
||
|
Repeatability (Cu) |
Rsd ≤ 4% |
Rsd ≤ 3% |
Rsd ≤ 2.5% |
|
||
|
Heating range of graphite Furnace |
Room temperature -3000 °C |
|||||
|
High power heating range |
1500-3000℃ |
|||||
|
Slope and hold time |
1-255s |
|||||
|
Heating rate |
Maximum heating rate: 2000 ℃/s |
|||||
|
Atomization heating mode |
Light-controlled heating, time-controlled heating, general heating |
|||||
|
Protective gas flow |
1 liter/minute |
|||||
|
External tubing |
4-speed adjustable (0, 50, 200, 250 L/min flow rate) |
|||||
|
Safety Protection |
Cooling water flow rate, protective gas pressure, furnace body temperature, power supply temperature, graphite furnace installation alarm |
|||||
|
Automatic sampler |
Optional |
|||||
|
Data Processing |
Measurement method |
Flame atomic absorption spectrometry, graphite furnace atomic absorption spectrometry, hydride generation atomic absorption spectrometry, flame emission spectrometry |
||||
|
Concentration calculation |
Standard curve method (6 linear/nonlinear fitting methods), standard addition method, interpolation method |
|||||
|
Method |
1-30 times, calculates and provides the average value, standard deviation, and relative standard deviation of absorbance/concentration |
|||||
|
Repeat measurements |
Parameter printing, data result printing |
|||||
|
Dimensions/Weight |
850x650 x 550mm/95kg |
|||||
|
Ambient Temperature |
10 ~ 35 °C |
|||||
|
Ambient Humidity |
≦85 % |
|||||
|
Power |
110/220V,50/60Hz |
|||||
Product More Details
1. The atomic absorption spectrophotometer is fully computer-controlled.
2. It can be flexibly equipped with optional graphite furnace, automatic sampler, and hydride generator.
3. It features a unique opto-mechanical design and a safe and convenient flame system.
4. Fully automatic instrument control, light source supports high-performance element lamps, allowing for rapid testing.
5. Simple, professional, automatic, and fully operational RG WIN AAS workstation software under the Microsoft Windows system.
6. Comprehensive and safe intelligent gas control module.
Name: Jennifer Zhang
Mobile:+86 13336040868
Tel:+86 13336040868
Whatsapp:+86 13336040868
Email:sales@iqctest.com
Add:No.51 of Xiba Road,Wuchang Street, Yuhang District, 311100 ,Hangzhou City, China